Benchmarking
Mass Flow Sensor Calibration with the Flusso FLS110
The Flusso FLS110 is an analog mass flow sensor. Its calibration algorithm converts the measured heat transfer of the flowing gas into a mass flow using a cubic polynomial. The heat transfer measurement is uncertain, yet systems today report the calibrated mass flow as a single number. This example runs the calibration routines of the Flusso FLS110 analog mass flow sensor [1], models the heat transfer as a uniform distribution, and computes the distribution of its calibrated mass flow output.

Figure 1. ...
When running on the Signaloid Cloud Compute Engine (SCCE), the calibration routines replace the usual approach of sampling followed by evaluation of each sample with a direct computation on a representation of the probability distribution. In a single computation, the SCCE computes the same output distribution that traditional Monte Carlo simulations require millions of iterations to achieve.

Figure 2. ...
The FLS110 mass flow calibration kernel, running on a single-threaded Signaloid C0Pro-S+ core, achieves runtimes 17550× faster than an optimized C-language Monte-Carlo-based implementation (i.e., the industry standard and status quo) of the same kernel running on an Amazon EC2 R7iz instance. With 95% confidence, a 16.6M-iteration Monte Carlo implementation matches the accuracy of the Signaloid UxHw-based version. If higher confidence is required for the Monte Carlo results, the speedup of the UxHw approach becomes even more pronounced.
[1] https://www.farnell.com/datasheets/3625949.pdf
Key Performance Indicator
Signaloid Platform Solution
Competing Solution
Signaloid Benefit
Speed for the same uncertainty quantification accuracy.
Run existing non-Monte-Carlo code and use either the Signaloid Compute Engine's automated ingestion of distribution information, or use the Signaloid UxHw API to set program variables as probability distributions.
Run existing Monte Carlo code, or, starting from non-Monte-Carlo code, modify code to implement Monte Carlo sampling, iteration, and aggregation of the results from the Monte Carlo iterations of the computation.
17550x faster execution time than 16.6M-iteration Monte Carlo, while achieving same fidelity of full distribution result.
Benchmarking Methodology
Monte Carlo simulations work by statistical sampling and therefore each multi-iteration Monte Carlo run will result in a slightly different output distribution. By contrast, Signaloid's platform is deterministic and each run produces the same distribution for a given Signaloid C0 core type.
The performance improvements are calculated by comparing Signaloid's platform with a Monte Carlo simulation of a similar quality of distribution. First, we run a large Monte Carlo simulation (about 50M iterations) on an AWS r7iz high-performance AWS instance: We use this distribution result as a baseline or ground truth reference of distribution quality. Then we calculate the performance of Signaloid's technology, and compare it with the performance of a Monte Carlo iteration count where the output distribution's Wasserstein distance (to the output distribution of the ground truth reference) is as accurate as the Signaloid-core-executed algorithm's output distribution, with 95% confidence level.